Manufacturer: CycloLab, BudapestIndia Supplier: Akira Analytical Solutions · Enquiries: +91 9391852431 · sales@akiralabs.com
Technical resource · India

CD-Screen-IEC 3 µm, 150 × 4 mm HPLC Column

A specialized analytical column developed for ionic cyclodextrin derivatives, with SBECD as a representative application area.

A specialized analytical column developed for ionic cyclodextrin derivatives, with SBECD as a representative application area.

Scientific illustration representing a CD-Screen HPLC column

Product specifications

Specifications for CD-Screen-IEC 3 µm, 150 × 4 mm HPLC Column
ProductCD-Screen-IEC 3 µm, 150 × 4 mm HPLC Column
Part NumberCDS-IEC-1504-03
Selector / TypeIon-exchange-type CD-Screen
Stationary PhaseSpecialized phase for ionic cyclodextrin derivatives
Particle Size3 µm
Dimensions150 × 4 mm
QualityAnalytical device

Technical overview

CD-Screen-IEC is the dedicated ion-exchange-type member of the portfolio. For SBECD and other ionic derivatives, a suitably developed method may support degree-of-substitution assessment, component-distribution characterization and determination of selected impurities. No single method should be assumed to work for every material or formulation.

Potential application areas

  • Ionic cyclodextrin derivative analysis
  • SBECD component-distribution studies
  • Degree-of-substitution assessment within a validated method
  • Selected impurity studies, including BCD, HBSA or DBSA where method-specific separation is demonstrated
  • Modified stability or degradation-related investigations

Method-development considerations

Actual retention, resolution and run time depend on the complete analytical system. Selection and operating conditions should consider analyte chemistry, sample matrix, detector compatibility, method goals, instrument pressure capability and validated system-suitability requirements.

Operating limits: do not assume pressure, pH, flow, temperature, flushing or storage limits from generic silica-column guidance. Refer to the current CycloLab manufacturer instruction manual or contact Akira Analytical Solutions for confirmed instructions.

India quotation and supply support

Akira Analytical Solutions Pvt. Ltd., Hyderabad, handles India quotation, supply and technical-enquiry support. Include the part number CDS-IEC-1504-03, quantity, analyte, matrix and current method when possible.

Quick answers

Frequently Asked Questions

Six concise answers to common questions about this page.

What is CD-Screen-IEC?

CD-Screen-IEC is an ion-exchange-type analytical CD-Screen column developed for ionic cyclodextrin derivatives.

What is the part number of CD-Screen-IEC?

The part number is CDS-IEC-1504-03.

What are the dimensions of CD-Screen-IEC?

CD-Screen-IEC is listed as a 150 × 4 mm column with 3 µm particles.

Can CD-Screen-IEC be considered for SBECD analysis?

Yes. SBECD is a representative application area for CD-Screen-IEC, subject to complete method development and validation.

Is CD-Screen-IEC the same stationary phase as standard CD-Screen?

No. CD-Screen-IEC is identified as an ion-exchange-type CD-Screen designed for ionic derivatives, while the standard formats list a (4-nitrophenyl)urea selector.

Who supplies CD-Screen-IEC in India?

Akira Analytical Solutions Pvt. Ltd., Hyderabad, provides India quotation, supply and technical-enquiry support.

CallEmailRequest Quote